Приказ основних података о документу

dc.creatorStanković, D.
dc.creatorDimitrijević, T.
dc.creatorKuzmanović, D.
dc.creatorKrstić, Milena
dc.creatorPetković, B. B.
dc.date.accessioned2020-06-03T14:03:08Z
dc.date.available2020-06-03T14:03:08Z
dc.date.issued2015
dc.identifier.issn2046-2069
dc.identifier.urihttps://vet-erinar.vet.bg.ac.rs/handle/123456789/1311
dc.description.abstractA simple and efficient procedure is described for electrochemical determination of trifluoperazine (TFP), a prominent compound in a large group of phenothiazine derivatives with potent physiological activity. This method is based on the electrochemical oxidation of TFP in Britton-Robinson buffer solution in pH 6 at a boron-doped diamond electrode. Cyclic voltammetry provided a four well defined oxidation peaks at + 0.65, + 0.83, + 1.06 and + 1.35 V (vs. Ag/AgCl/3 M KCl electrode). Differential pulse voltammetry was applied as a very sensitive analytical technique for the determination of micromolar amounts of TFP. Two oxidation peaks on higher potentials were chosen for quantification of TFP. Under optimized conditions, the analytical curves obtained were linear in the TFP concentration range of 1.0 to 37.0 mmol L-1, with a detection limit of 0.7 and 0.6 mmol L-1, respectively. The effect of interfering agents (common urinary compounds) appeared to be negligible confirming the favourable selectivity of the method. The proposed method was analytically applied by determination of trifluoperazine content in model human urine samples with good accuracy (recoveries varied from 97% to 104%). The developed approach could be beneficial in analysis of TFP in biological samples using a boron-doped diamond electrode as an up-to-date electrochemical sensor and could represent an inexpensive analytical alternative to separation methods.en
dc.publisherRoyal Soc Chemistry, Cambridge
dc.relationinfo:eu-repo/grantAgreement/MESTD/Integrated and Interdisciplinary Research (IIR or III)/45022/RS//
dc.rightsopenAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc/4.0/
dc.sourceRSC Advances
dc.titleVoltammetric determination of an antipsychotic agent trifluoperazine at a boron-doped diamond electrode in human urineen
dc.typearticle
dc.rights.licenseBY-NC
dcterms.abstractКрстић, Милена; Кузмановић, Д.; Димитријевић, Т.; Петковић, Б. Б.; Станковић, Д.;
dc.citation.volume5
dc.citation.issue129
dc.citation.spage107058
dc.citation.epage107063
dc.citation.other5(129): 107058-107063
dc.citation.rankM21
dc.identifier.wos000367274300084
dc.identifier.doi10.1039/c5ra18783d
dc.identifier.scopus2-s2.0-84952033905
dc.identifier.fulltexthttps://vet-erinar.vet.bg.ac.rs/bitstream/id/277/1310.pdf
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу