Приказ основних података о документу

dc.creatorPérez-Ramírez, Elisa
dc.creatorCano-Gómez, Cristina
dc.creatorLlorente, Francisco
dc.creatorVodica, Ani
dc.creatorVeljović, Ljubiša
dc.creatorToklikishvilli, Natela
dc.creatorSherifi, Kurtesh
dc.creatorSghaier, Soufien
dc.creatorOmani, Amel
dc.creatorKustura, Aida
dc.creatorKrstevski, Kiril
dc.creatorKarayel-Hacioglu, Ilke
dc.creatorHagag, Naglaa Mohamed
dc.creatorHage, Jeanne El
dc.creatorDavdyan, Hasmik
dc.creatorBintarif, Mohd Saddam
dc.creatorAdžić, Bojan
dc.creatorAbouchoaib, Nabil
dc.creatorJiménez-Clavero, Miguel Ángel
dc.creatorFernández-Pinero, Jovita
dc.date.accessioned2021-02-24T08:36:39Z
dc.date.available2021-02-24T08:36:39Z
dc.date.issued2020
dc.identifier.issn2076-0817
dc.identifier.urihttps://vet-erinar.vet.bg.ac.rs/handle/123456789/2019
dc.description.abstractThe increasing incidence of West Nile virus (WNV) in the Euro-Mediterranean area warrants the implementation of effective surveillance programs in animals. A crucial step in the fight against the disease is the evaluation of the capacity of the veterinary labs to accurately detect the infection in animal populations. In this context, the animal virology network of the MediLabSecure project organized an external quality assessment (EQA) to evaluate the WNV molecular and serological diagnostic capacities of beneficiary veterinary labs. Laboratories from 17 Mediterranean and Black Sea countries participated. The results of the triplex real time RT-PCR for simultaneous detection and differentiation of WNV lineage 1 (L1), lineage 2 (L2) and Usutu virus (USUV) were highly satisfactory, especially for L1 and L2, with detection rates of 97.9% and 100%, respectively. For USUV, 75% of the labs reported correct results. More limitations were observed for the generic detection of flaviviruses using conventional reverse-transcription polymerase chain reaction (RT-PCR), since only 46.1% reported correct results in the whole panel. As regards the serological panel, the results were excellent for the generic detection of WNV antibodies. More variability was observed for the specific detection of IgM antibodies with a higher percentage of incorrect results mainly in samples with low titers. This EQA provides a good overview of the WNV (and USUV) diagnostic performance of the involved veterinary labs and demonstrates that the implemented training program was successful in upgrading their diagnostic capacities.
dc.publisherMDPI AG
dc.rightsopenAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourcePathogens
dc.subjectDiagnostics
dc.subjectELISA
dc.subjectExternal quality assessment (EQA)
dc.subjectFlavivirus
dc.subjectMediLabSecure
dc.subjectPCR
dc.subjectUsutu virus (USUV)
dc.subjectWest Nile virus (WNV)
dc.titleEvaluation of west nile virus diagnostic capacities in veterinary laboratories of the mediterranean and black sea regions
dc.typearticleen
dc.rights.licenseBY
dcterms.abstractСхерифи, Куртесх; Омани, Aмел; Кустура, Aида; Крстевски, Кирил; Хагаг, Наглаа Мохамед; Давдyан, Хасмик; Бинтариф, Мохд Саддам; Караyел-Хациоглу, Илке; Хаге, Јеанне Ел; Aджић, Бојан; Јимéнез-Цлаверо, Мигуел Áнгел; Фернáндез-Пинеро, Јовита; Токликисхвилли, Натела; Сгхаиер, Соуфиен; Aбоуцхоаиб, Набил; Пéрез-Рамíрез, Елиса; Цано-Гóмез, Цристина; Ллоренте, Францисцо; Водица, Aни; Вељовић, Љубиша;
dc.citation.volume9
dc.citation.issue12
dc.citation.spage1
dc.citation.epage20
dc.citation.rankM22
dc.identifier.wos000602425500001
dc.identifier.doi10.3390/pathogens9121038
dc.identifier.scopus2-s2.0-85097681600
dc.identifier.fulltexthttps://vet-erinar.vet.bg.ac.rs/bitstream/id/5459/Evaluation_of_west_pub_2020.pdf
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу